ARCHIPELAGO
Lighting Group
Catalog Number
LBLR24-33MXP1
LBLR · retroⒶRCH-P1
Retrofit back-lit LED panel · drop-in replacement for standard GT8/2GT8 lensed fluorescent troffers · 3-WATTselect × 3-CCTselect dip-switch · 27 field configurations from 3 catalog SKUs · 125 LM/W constant · TAA Compliant (Made in Mexico) · DLC Listed · 5-year warranty
Field-Adjustable
3-WATTselect dip-switch (LBLR14 + LBLR22: 18/26/35W · LBLR24: 26/35/44W) ·
3-CCTselect dip-switch (3500/4000/5000K) ·
backⒶLIT uniform back-lit panel technology ·
TAA Compliant (Made in Mexico · federal procurement) ·
contrⒶLS-Ready sensor mount (/SRR or /SRT)
ARCHIPELAGO
Lighting Group
Catalog Number
LBLR24-33MXP1
Specifications
LBLR retroⒶRCH-P1 · 1×4 / 2×2 / 2×4 retrofit panel · 18-44W
| Construction |
| Housing | SPCC steel housing + aluminum trim · lightweight retrofit-grade construction |
| Diffuser | PMMA white diffuser · precision-engineered back-lit (NOT edge-lit) for uniform 120° light output across the full panel face |
| Drop-In Pattern | Direct same-aperture replacement for standard GT8 (1×4) / 2GT8 (2×2 + 2×4) lensed fluorescent troffers · LUMCAT verified in IES bundle |
| Ingress | IP40 indoor · UL Damp Location rated |
| Operating Temp | -4°F to +104°F (-20°C to +40°C) ambient · commercial + cold-corridor capable |
| LED & Optics |
| LED Source | High-efficiency SMD LEDs · LM80 compliant · IP-Protected light engine |
| CCT Options | 3-CCTselect dip-switch · 3500K / 4000K / 5000K ★ (default 5000K) |
| CRI | > 80 (R9 > 0 per datasheet body · commercial-ambient tier · heads up: not 90+ spec-grade) |
| Distribution | 120° uniform back-lit panel distribution · zero upward emission · same throw pattern as the fluorescent troffer being replaced |
| Lumen Maintenance | 95.8% @ 6,000 hrs (LM-80 verified) · L70 @ 50,000 hrs · LED color shift warrantied <180K over the warranty period |
| Lumen Output | LBLR14: 2,200-4,400 lm · LBLR22: 2,200-4,400 lm · LBLR24: 3,300-5,500 lm · 125 LM/W constant across the dial |
| Driver & Electrical |
| Voltage | 120-277V Universal · intelligent non-isolated driver · >0.9 PF · non-flicker · <20% THD |
| 3-WATTselect | 3-position DIP switch · LBLR14 + LBLR22: 18/26/35W · LBLR24: 26/35/44W · 9 configs per class |
| 3-CCTselect | 3-position DIP switch · 3500K / 4000K / 5000K · 9 configs per class · 27 field configs across 3-SKU catalog |
| Dimming | 0-10V continuous with Dim-to-Off (NOT a 10% floor · rare in retrofit category) |
| Power Factor | > 0.9 Non-Flicker |
| THD | Low Harmonic Distortion |
| Starting Time | < 0.5 seconds |
| Dimming | 0-10V continuous · contrⒶLS-DMX optional via accessory · flicker-free operation |
| Controls & Connectivity |
| Sensor Mount | /SRR (Sensor Ready Recessed) or /SRT (Sensor Ready Trim) · spec at order · snap-in compatible |
| Bi-Level | MSM-HTI/08P1/BLS (Microwave) + MSP-HTI/08P1/BLS (PIR) · 13FT max mount · IR Remote commissioning |
| contrⒶLS by ⒶCS | Bluetooth Mesh networking via MSP-ACS / MSP-20CM-ACS / MSP-40CM-ACS · DLC NLC qualified for Title 24 § 130.1 rebate adder |
| contrⒶLS by SILVAIR | Enterprise Bluetooth Mesh NLC variants · SaaS commissioning for multi-tenant + campus deployments |
| Emergency | constⒶNT EM08-MT/150DC factory-install option · UL 924 · NFPA 101 90-min egress |
| Install Pattern |
| Drop-In Retrofit | Direct replacement install for standard GT8 / 2GT8 lensed fluorescent troffers · uses existing ceiling cutout + existing junction box · no ceiling rework required |
| Wiring | Hardwire to existing line-voltage feed · ballast bypass · can wire directly to existing fluorescent T8/T12 line input |
| Install Time | Typical 15-20 minutes per fixture for trained electrician (vs full ceiling-tile pull + new can on a new-construction equivalent) |
| Ceiling Compatibility | Standard 15/16″ and 9/16″ T-bar drop-ceiling grids · works in any space currently lit by standard GT8/2GT8 troffers |
| Replacement Inventory | LBLR14 replaces 1×4 GT8 troffers · LBLR22 replaces 2×2 2GT8 · LBLR24 replaces 2×4 2GT8 · full LUMCAT verification in the IES bundle |
| Compliance & Certifications |
| Standards | ETL Listed (Intertek US/CA) · DLC Listed (supplier rates Premium-equivalent · ALG markets at Listed) · FCC Title 47 Part 15B · RoHS · UL Damp Location · LM-79 · LM-80 |
| Country of Origin | Made in Mexico · TAA Compliant (designated TAA country for federal procurement) |
| Warranty | 5-Year limited · full warranty (same as new construction equivalents) · LM-80 color-shift coverage |
ARCHIPELAGO
Lighting Group
Catalog Number
LBLR24-33MXP1
Dimensions & Drop-In Install
3 SKU classes · LBLR14 / LBLR22 / LBLR24 · same-aperture replacement for standard GT8/2GT8
LBLR14 · 1×4
LBLR22 · 2×2
LBLR24 · 2×4 ★
| SKU Class |
Replaces |
Watt Range |
Lumen Range |
Configs |
| LBLR14-33MXP1 · 1×4 | standard GT8 lensed 1×4 fluorescent | 18 / 26 / 35W ★ | 2,200 - 4,400 lm | 9 (3W × 3CCT) |
| LBLR22-33MXP1 · 2×2 | standard 2GT8 lensed 2×2 fluorescent | 18 / 26 / 35W ★ | 2,200 - 4,400 lm | 9 (3W × 3CCT) |
| LBLR24-33MXP1 · 2×4 ★ | standard 2GT8 lensed 2×4 fluorescent | 26 / 35 / 44W ★ | 3,300 - 5,500 lm | 9 (3W × 3CCT) |
| Drop-In Retrofit Process |
| 1 · Power-Down | De-energize the existing fluorescent troffer at the breaker |
| 2 · Remove Fluorescent | Remove existing T8/T12 lamps, ballast, and lens (existing ceiling cutout + junction box stay) |
| 3 · Wire LBLR | Hardwire LBLR retroⒶRCH-P1 directly to the existing line-voltage feed (120-277V universal) · no separate driver/ballast install needed |
| 4 · Set Dip-Switches | 3-WATTselect + 3-CCTselect dip-switches on the LED driver · field-set at install per spec sheet |
| 5 · Mount + Restore Power | Snap LBLR into the existing T-bar grid · restore breaker · verify 0-10V dimming + sensor function if /SRR or /SRT spec'd |
| Typical Time | 15-20 minutes per fixture for a trained electrician · significantly faster than full ceiling-tile pull + new construction install |
| Form Factor & Construction |
| Housing | SPCC steel housing + aluminum trim · lightweight retrofit construction |
| Diffuser | PMMA white back-lit diffuser · uniform light output across the full panel face |
| LED Array | Back-lit configuration (NOT edge-lit) · even brightness across the panel face · back-lit panels reduce hot-spotting vs edge-lit alternatives |
ARCHIPELAGO
Lighting Group
Catalog Number
LBLR24-33MXP1
Ordering Information
Configure your catalog number
| Segment |
Available Codes |
| LBLR | retroⒶRCH-P1 family · planoⒶRCH PRO Retrofit Back-Lit Panel |
| 14 / 22 / 24 | Size class — 1×4 (LBLR14) · 2×2 (LBLR22) · 2×4 (LBLR24) ★ |
| 33 | 3-WATTselect × 3-CCTselect dip-switch positions (3W: 18/26/35 on 1×4+2×2 · 26/35/44 on 2×4 · 3CCT: 3500/4000/5000K) |
| MXP1 | Series suffix — Made in Mexico retroⒶRCH-P1 (constant for the entire family · TAA Compliant signifier) |
| /SRR or /SRT | Optional sensor mount — Sensor Ready Recessed (/SRR) or Sensor Ready Trim (/SRT) · specify at order if installing contrⒶLS sensors |
| /W20 to /W50 | Optional factory-lock watt — collapses 4-WATTselect to a single fixed value (e.g. /W35 = 35W locked) · Workbench assembly |
| /C30 to /C50 | Optional factory-lock CCT — collapses 4-CCTselect to a single fixed value (e.g. /C40 = 4000K locked) · Workbench assembly |
| Accessory |
Order Code |
| EM Battery | EM08 (8W Factory-Install) · EM15 (15W) · EM15-CL (15W + constⒶNTLink) — order separately as line items |
| Bi-Level Sensor | MSM-HTI/08P1/BLS (Microwave) · MSP-HTI/08P1/BLS (PIR) — 13FT max mount · IR Remote commissioning |
| ⒶCS Sensor | MSP-HTI/08P1/ACS (8FT) · MSP-20CM-ACS (20FT) · MSP-40CM-ACS (40FT) · MSX-CTI/08P1/ACS (Fixture Hub) · MSX-CTI/LV20/ACS (J-Box Hub) · 50WM-ACS (Kinetic Switch) |
| SILVAIR NLC | MSM/MSP-HTI/08P1/NLC · MSM/MSP-SRI/903P1/NLC · MSX-CTI/LV5/NLC — enterprise Bluetooth Mesh |
| Sensor Mount | /SRR (Sensor Ready Recessed) or /SRT (Sensor Ready Trim) · spec at order · no separate accessory SKU |
| Step-Down Transformer | SDT-HTI/325 · for 347/480V applications · same accessory as Luxmark / Astra-I families |
Ordering example: LBLR24-33MXP1/SRR/W44/C50
= 2×4 retrofit panel · 3W × 3CCT dip · Made in Mexico retroⒶRCH-P1 · Sensor Ready Recessed · factory-locked 44W · factory-locked 5000K
Base catalog example (field-selectable): LBLR24-33MXP1
= 2×4 retrofit panel · 3-WATTselect · 3-CCTselect · Made in Mexico retroⒶRCH-P1 · contractor sets W + CCT at install via dip-switch · sensor accessory ordered separately
Photometric Data
LBLR24 · 44W · 3500K · LM-79 measured (3500K IES only · 4000/5000K factory data on request)
| Peak Candela | 1,881 cd |
| Total Lumen Output | 5,442 lm |
| Beam Angle | 120° uniform back-lit panel |
| Distribution | Uniform back-lit panel · zero upward emission · same throw pattern as fluorescent fixture being replaced |
| Measured Efficacy | 131.3 LM/W @ 41.4W actual |
| Datasheet Headline | 125 LM/W @ 44W nominal (LBLR24 max) |
| Test Standard | IESNA LM-79 · EVERFINE GO-2000B |
| Test Date | 2023-09-26 |
| IES File | LBLR24-44W-3500K_IESNA95.IES |
IES bundle covers 3 SKU classes at default WATT/3500K only · 4000K + 5000K + intermediate WATT settings available as factory data on request. LM-79 testing by LEADING TESTING LABORATORIES 2025-02. LUMCAT field identifies the fluorescent troffer being replaced (standard GT8/2GT8 lensed).
ETL Listed
DLC Listed
FCC 47 / 15B
RoHS
UL Damp Location
IP40 Indoor
TAA Compliant
5-yr Limited
LM-79 / LM-80